N2S250-25-24VDC | 1 NPT Stainless Steel Normally Closed Solenoid Valve
The Pneuforce N2S250-25-24VDC is a 1 NPT, two-way normally closed 316 stainless steel solenoid process valve for on/off control of compatible water, compressed air and vacuum lines. It has a 25 mm internal orifice (Cv 12) and a 24VDC coil.
Its mechanically coupled diaphragm operates with no minimum pressure differential across the valve, making the N2S series useful in low-pressure, gravity-fed and vacuum systems where some pilot-operated valves cannot function. The 24VDC version is rated to 120 psi (8 bar) gauge according to the series datasheet; confirm temperature, seal and flow requirements for the intended fluid.
Technical Specifications
| Specification | Details |
|---|---|
| Model / Part Number | N2S250-25-24VDC |
| Valve Series | N2S process solenoid valve |
| Valve Function | 2/2-way, normally closed (on/off) |
| Wetted Metal Construction | 316 stainless steel body and stainless steel wetted metal internals |
| Connection | 1 NPT female ports |
| Internal Orifice Diameter | 25 mm |
| Flow Coefficient | Cv 12 |
| Coil Voltage | 24VDC |
| Rated Working Pressure | 0 to 120 psi (8 bar) gauge; observe other duty limits |
| Minimum Differential Pressure | 0 psi (coupled-diaphragm design) |
| Standard Seal | NBR; 14 to 176°F (-10 to 80°C) |
| Optional Seal | Viton / FKM available by request; 5 to 248°F (-15 to 120°C) in series datasheet |
| Nominal Media | Water, air and vacuum; steam is listed by the series, subject to seal and temperature approval |
| Coil Duty and Protection | Continuous duty; Class H, IP65 when correctly assembled and connected |
| Electrical Connector | DIN 43650 Form A connector included |
How the Coupled-Diaphragm Valve Works
When power is removed from the 24VDC coil, the valve returns to its normally closed position and shuts off the process line. Energizing the coil lifts the coupled diaphragm to open the 25 mm flow path. Unlike a conventional pressure-assisted pilot valve, the mechanically linked diaphragm does not need inlet pressure to exceed outlet pressure by a set minimum.
This makes zero-differential operation useful on vacuum and low-static-head systems. The Cv value is an aid to flow sizing; it does not tell you the actual flow rate without the fluid properties, pressure drop and piping conditions.
Applications: Industrial, Commercial and Domestic
The 1 NPT connection and Cv 12 make this model a candidate for equipment manifolds, medium-flow water branches and plant-utility distribution. These are application examples, not approvals for every medium or installation.
Industrial and OEM equipment
- Equipment-cooling water circuits, washdown utility supply and process rinse-water isolation.
- Bulk air distribution or vacuum manifold isolation on machinery requiring more flow than a small branch valve.
- Automated tank fill and drain transfer lines where on/off control and sufficient pressure head are available.
- Stainless wetted construction is advantageous where corrosion resistance is required; compatibility with each liquid and seal must still be checked.
Commercial and building services
- HVAC utility-water distribution, building plant-room services and non-potable water-treatment skids.
- Commercial wash equipment, fountains and irrigation branch manifolds.
- Useful for industrial or building-service sites requiring stainless wetted metal parts, without implying food or drinking-water certification.
Domestic and property maintenance
- Larger residential irrigation or rainwater-pumping circuits, when the rated flow and pipe size are appropriate.
- Detached workshop compressed-air or non-potable water lines with suitable protective installation.
Selecting the Right Valve for the Duty
Choose the 1 NPT thread to match the pipework, then size by required flow and pressure drop using Cv 12 rather than using nominal pipe size alone. Select the 24VDC coil for the available control supply. The valve is an on/off device, not a proportional flow-control valve.
The stainless steel body and internals provide better resistance to many wet or aggressive environments than general-purpose brass, but stainless steel is not universally compatible with every chemical.
Steam and temperature: The Pneuforce series datasheet lists steam as a working medium, but standard NBR seals are rated only to 176°F (80°C); optional Viton is listed to 248°F (120°C). These limits alone do not verify a specific steam duty. Confirm the installed seal, pressure, steam temperature and manufacturer approval before specifying steam service.
Installation and approvals: For water service, verify wetted-material compatibility and local plumbing requirements. Do not assume drinking-water, food-contact, fuel-gas or safety shutoff approval: no such certification is established by the series datasheet. Verify vacuum leak tightness where required, fit within operating ratings and use appropriate electrical protection.
Frequently Asked Questions
Why is N2S250-25-24VDC suitable for zero-differential or low-pressure applications?+
The coupled diaphragm is mechanically lifted by the solenoid, so the valve does not require a minimum pressure differential across its inlet and outlet. This is useful on low-pressure water feeds and vacuum lines, although flow still depends on the available head and piping.
Can N2S250-25-24VDC control vacuum as well as compressed air?+
The series is designed for zero-differential operation, including vacuum duty. Confirm the actual vacuum level, seal condition, leakage requirement and installation conditions; the datasheet does not provide a quantified vacuum leak-rate guarantee.
Can I install this 1 NPT valve on a gravity-fed water tank?+
Potentially yes: its coupled-diaphragm mechanism can actuate without the minimum inlet-to-outlet differential required by many pilot valves. The available water flow is still limited by tank head, pipe losses and the Cv rating; check plumbing suitability and avoid assuming potable-water approval.
Is the N2S250-25-24VDC suitable for steam?+
Steam is listed among the series working media, but a standard NBR seal is limited to 176°F (80°C). The optional Viton specification extends to 248°F (120°C); temperature limits do not by themselves establish steam compatibility. Confirm the fitted seal and the exact steam temperature and pressure with the manufacturer before use.
What is the difference between 1 NPT ports and the 25 mm orifice?+
1 NPT identifies the threaded pipe connection. The internal flow opening is 25 mm, and the published valve flow coefficient is Cv 12. Select the valve using the flow requirement and expected pressure drop, not the thread size alone.
What happens to N2S250-25-24VDC if the 24VDC power supply fails?+
This is a normally closed valve: when the 24VDC coil is de-energized, it returns to the closed position. It is intended for ordinary process isolation, not as a certified emergency or fuel-gas safety shutoff.
What industrial and commercial systems commonly use a 1 NPT valve?+
Examples include equipment manifolds, medium-flow water branches and plant-utility distribution, provided the required Cv, media compatibility, temperature, operating pressure and electrical requirements are satisfied.
Why choose an N2S stainless valve instead of an N2W brass valve?+
N2S uses stainless wetted construction, making it a better candidate for some corrosive or demanding industrial water services. N2W uses brass. Neither material guarantees compatibility with every fluid, and the sealing material is a separate selection requirement.
Is 316 stainless steel appropriate for process water and drinking water?+
The stainless construction may be preferred for corrosion resistance, but compatibility still depends on water chemistry and seals. No NSF/ANSI 61 or other potable-water certification has been established for this product, so it must not be assumed suitable for drinking-water supply.
Is the 24VDC coil supplied with a connector, and can it remain energized?+
The series datasheet specifies a Form A DIN connector and continuous-duty coil. This complete valve includes the matching DIN connector. Apply 24VDC only, provide appropriate wiring protection, and follow the installation instructions; coil heating during sustained use can be normal.
Series data: Pneuforce N2W/N2S technical datasheet. Application examples require engineering verification.
Ships from Indianapolis, USA